Characteristics of the vibrocryotribometer (VCTM bench)

Contact geometry : 

  • Sphere / plane (adjustable sphere radius)

  • Plane / plane

Kinematics :

  • alternative : amplitude from 1 to 1000 micro-m, frequency from 1 to 600Hz

Loading :

  • Constant normal force : 30 to 300 N
  • Measured tangential force : 1 to 300 N

Ambient :

  • T° from -196°C to +250°C
  • LN2, Air, water, oil

Applications : contact fatigue by small deflections (fretting-fatigue) and wear (fretting-wear). In this test method, the specimens are not volumetrically stressed.

Characteristics du vibrothermotribometer (banc VTTM)

Contact Geometry : 

  • Sphere / plane (adjustable sphere radius)

  • Plane/plane

Kinematics :

  • amplitude from 1 to 1000 micro-m, frequency from 1 to 100Hz

Loading :

  • Constant normal force : 10 to 500 N
  • Measured tangential force : 1 to 450 N

Ambient :

  • Ambient temperature to +650°C
  • Air

Applications : contact fatigue by small deflections (fretting-fatigue) and wear (fretting-wear). In this test method, the specimens are not stressed volumetrically.

 
Localisation : ISAE-SUPMECA

contact : equipements@isae-supmeca.fr